ST-1400 Specifications
Vibratory Feeder Controls
Single, Dual, and Triple Units (15 Amp Capacity)
The ST-1400 Series of Controls are used to operate vibratory bowls
with part sensing, and storage hoppers fitted with electronic bowl
level detectors. The demand cycling of the bowl or hopper is controlled
by an external input signal processed through the Remote Hold and
time delay settings of the unit if selected. The units are operational
in both Open Loop and Closed Loop (sensor option) mode.
· Soft-Start is switch selectable which allows the feeder
bowl to cycle on gently. A ramped ‘on cycle’ of approximately
0.8 seconds keeps piece parts from falling off the tooling when
the bowl turns ‘On’ upon track level sensor demand.
In addition, the tooling, drive mechanism, and drive springs are
shocked less with each ‘On’ cycle.
· Line regulation allows the control’s
output to compensate for fluctuations in the supply voltage.
· A Run Interlock
Input (Remote Hold) is
provided so the control can also be turned On/Off, (Hold mode),
by a PLC or other
feeder control. This input is jumper selectable. Remote Hold can
be controlled by an NPN or PNP track level sensor, dry contact
closure or 5 volts RMS minimum to 120 volts RMS maximum (AC or
DC) voltage input
· A Power Output
Range Select (Open Loop Mode) adjustment
allows the control to be preset for the maximum output of the main
control potentiometer. By limiting the ‘Full On’ output,
an operator cannot turn the main potentiometer up to high. This
feature can prevent destructive hammering of the drive coils, tooling
cracks, and spring breakage.
· On and Off Delays are independently adjustable
to provided (0-15 sec) timing for the track level sensor. This
allows a precise
level of part flow to be maintained to the machine.
· 120 Vac and 220 Vac Models are available,
and will operate on either 50 Hz or 60 Hz line frequency.
· Frequency Selectable Outputs are available.
30Hz, 40Hz, 60Hz and 120Hz for 60 cycle line frequency. 25Hz,
33.3Hz, 50Hz
and 100Hz for 50 cycle line frequency
· Phase Select feature enables which phase
of the line voltage the controller triggers off of on the 30Hz
and 60Hz frequency
output selection only. This allows balancing of the source when
multiple units are utilized
· Operate / Hold Out (Interlocking) This
is a unit functional output of +5 Vdc indicating Operate mode
and a 0 Vdc output indicating
the controller is in Hold mode. This function is used not only
for indication but also for multiple controller interlocking control.
View
printable version of this page
|